Transformer Calculations¶
Here I will share various transformer related equations.
Turns per Volt¶
Turns per volt,
Where:
- Acore is area of the transformer core.
- Bmax – Maximum flux density in Tesla. For normal steel materials it can be taken as 1.5T.
- f is frequency. Usually 50 or 60 for main supplies.
Core Area Required¶
Core area,